Products
YG28001-YALEPIC-MagEVO-Pathogenic-Microbes-DNA-RNA-Extraction-Kit

YALEPIC® MagEVO Pathogenic Microbes DNA/RNA Extraction Kit

Maximum Yield, Minimum Noise — Reliable DNA and RNA Isolation from pathogenic microbes (automated) via magnetic bead

An optimized magnetic bead workflow that turns pathogenic microbes (automated) into high-quality DNA and RNA ready for downstream applications.

Number Specifications Catalog Price Add To Cart
YG28001 96T Online Consult +
YG28001-A (Prepackaged) 32T Online Consult +
YG28001-B (Prepackaged) 48T Online Consult +
YG28001-C (Prepackaged) 96T Online Consult +

Product Description

YALEPIC® MagEVO Pathogenic Microbes DNA/RNA Extraction Kit is a reagent kit designed for efficient purification of host and microbial genomic DNA from various biological samples such as blood, bronchoalveolar lavage fluid, liquefied sputum, nasal or oropharyngeal swabs, pleural or peritoneal fluid, cerebrospinal fluid, and amniotic fluid. This kit utilizes silica-based magnetic beads for specific adsorption and enrichment of microbial DNA, yielding DNA suitable for various downstream applications including PCR, qPCR, metagenomic or 16S rDNA library construction experiments.

Features

  • Simple and fast: The whole proceess takes  only 30 min to obtain one sample.
  • High yield and good integrity: Extract high quality DNA /RNA from blood, bacterial cultures, fungal cultures, swab wahses, and tissuse etc.
  • Automated extraction: This kit can be used with automated nucleic acid extraction instrument for high-throughput extraction.

Application

Blood Samples: ≤ 400 μl Fresh or frozen anticoagulated whole blood.

Body Fluid Samples: Bronchoalveolar lavage fluid(BALF), Cerebrospinal fluid (CSF), Pleural fluid/Ascites, Sputum.

Swab Eluate Samples: Nasal, oropharyngeal, or oral swabs.

Microbial Samples: Bacteria:≤ 1 × 10⁹ cells, Fungi: ≤ 1 × 10⁹ cells.

Storage

Transport at room temperature.

Storage at 10 ~ 30°C for one year.

What sample types can the MagEVO Pathogenic Microbes DNA/RNA Extraction Kit be used for?

This kit is suitable for various clinical and environmental samples, including: fresh or frozen anticoagulated whole blood (<=400 microL), nasopharyngeal swabs, sputum, bronchoalveolar lavage fluid, cerebrospinal fluid, pleural or ascitic fluid and other body fluid samples (2-3 ml, <=5x10^6 cells), bacterial (<=1x10^9 cells) and fungal (<=1x10^9 cells) microbial cultures, and also supports DNA/RNA extraction from stool samples (100 mg solid or 200 microL stool in preservation medium).

Can this kit extract both DNA and RNA simultaneously?

Yes. The kit is specifically optimized for co-extraction of pathogenic microbial DNA and RNA, capable of simultaneously extracting and purifying DNA and RNA from viruses, bacteria, and fungi in the same sample. This feature is particularly suitable for metagenomic sequencing and pathogen co-detection applications requiring simultaneous DNA virus and RNA virus detection.

How is the extraction performance for fungi or Gram-positive bacteria that are difficult to lyse?

This kit uses a lysis system combining chemical lysis and mechanical grinding, with lysis optimization for fungi (such as yeast, Candida) and Gram-positive bacteria with thick cell walls that are difficult to lyse. It can efficiently release nucleic acids, significantly improving the detection rate of such microorganisms, suitable for low-abundance pathogen detection in clinical samples.

What downstream experiments can the extracted nucleic acid products be used for?

The purified DNA/RNA products have high purity, good integrity, and no protein or nuclease residue, suitable for various downstream molecular biology applications, including: conventional PCR and real-time quantitative PCR (qPCR), metagenomic library construction (mNGS), whole-genome sequencing (WGS), 16S rDNA-based microbiome analysis, and shotgun metagenomic sequencing analysis.

Does the kit support automated extraction?

Yes. This kit uses magnetic bead-based technology, compatible with both manual extraction using a magnetic rack and fully compatible with various magnetic rod-based and pipetting-based automated nucleic acid extraction instruments for high-throughput extraction, suitable for large-scale sample processing needs in clinical testing centers, CDC, and research laboratories.

Does the kit contain phenol or chloroform or other toxic reagents?

No. This kit uses nano-magnetic bead purification technology, requiring no phenol, chloroform, or other toxic organic solvents throughout the process. The extraction process does not involve organic reagent extraction steps, making it safer for laboratory personnel and compliant with green environmental laboratory practices.

What are the storage and transport conditions for the kit? What is the shelf life?

This kit supports ambient temperature transport, requiring no cold chain throughout. All components can be stored at room temperature (10-30 degrees C), with a shelf life of 12 months. These storage conditions greatly reduce cold chain costs during transport and storage, facilitating laboratory inventory and daily use.

What is the extraction yield of this kit? What purity level can be achieved?

The MagEVO kit is optimized for high yield and good reproducibility. The purified DNA/RNA products typically have an A260/A280 ratio between 1.8-2.0, with low protein residue. The purified products are free of PCR inhibitors and nucleases, and can be directly used for downstream amplification and sequencing reactions without additional purification.

Can it be used for sputum and other samples rich in mucin and inhibitors?

Yes. This kit has undergone specific buffer optimization for sputum, bronchoalveolar lavage fluid, and other complex body fluid samples rich in mucin and various PCR inhibitors. Combined with efficient washing steps, it can effectively remove inhibitors from samples, ensuring that the extracted nucleic acid purity meets downstream detection requirements.

What special requirements does metagenomic sequencing (mNGS) have for nucleic acid extraction?

mNGS has high requirements for nucleic acid extraction purity, integrity, and background bacterial contamination control. This kit uses an efficient washing system that maximally removes host nucleic acid interference and background bacterial contamination, with purified products suitable for mNGS library construction. Use NGS-grade water and nuclease-free consumables during mNGS experiments, and set up negative controls during extraction to monitor background contamination.

Related Products
+86-512-66256010